MSB vs. LSB

  • p.5: … words are addressed by the location of their lowest numbered byte
  • p.47: prog 2.2: “LDA three” and storage directive “three WORD 3” … seems as MSB
  • What is lowest numbered byte? Is this LSB?
  • Decision: We use MSB!

Register numbers

  • p.5: PC=8, SW=9 due to compatibility with XE
  • Why is number 7 unused?
  • Number 9=10001b does not fit into 4 bits, e.g., in instructions ADDR, …
  • Better would be PC=7, SW=8

Multiple sections with the same name

  • Is this allowed?
  • No. Since, the CSECT format is: CSECT and labels are unique.
  • However, the assembler could easily be extended to support section reentry.
  • Decision: by the book, no section reentry.

Addressing resolution

  • p.59
  • first try PC-relative, then base-relative
  • if neither is applicable programmer must use format 4 (extended)
  • So when direct/absolute addressing can be used? Only for absolute symbols?
  • Can we after PC-rel and base-rel have failed use direct? See also next point.

Direct/absolute addressing in format 3 and SIC format

  • Renders the code unrelocatable.
  • In particular, it is unrelocatable only in the range of 12 bit displacement.
  • Should we use this mode?

Immediate with negative operands

  • e.g., LDA #-1
  • use of direct/absolute addressing
  • however in simple and indirect operand gives the absolute address, thus it is unsigned
  • can in the case of immediate addressing the operand be signed.
  • Decision: the assembler treats immediate as signed, all other as unsigned

Directive ORG value

  • p.73: “value is a constant or an expression involving constants and previously defined symbols”
  • Can we use forward reference? At least to absolute symbols. Yes?
  • Thus, expressions consists of constants and symbols (absolute or (relative) previously defined)

Directive ORG and length of code?

  • How does one calculate code length if it contains ORG:
    • so there is a large non-assembled gap, or
    • there ORG address is before start address (we have negative code length)
  • See also p. 74 for a discussion on ORG (without parameter) used for resetting to the previous value.
  • Decision:
    • At the end of every section we implicitly issue ORG (reset the locctr).
    • Then we calculate the length.
    • Consequently, we ignore all the “ORG address” parts.